Anti-HTLV-1 and Anti-HTLV-2 screening and confirmation

Bloodborne Virus Laboratory

For use in testing for the presence of Human T-cell lymphotropic virus.

Area

Health Science

Lab name

Bloodborne Virus Laboratory

Lab location

Wallaceville Science Centre, Upper Hutt

Test name

Anti-HTLV-1 and Anti-HTLV-2 screening and confirmation

Organisms

Human T-cell lymphotropic virus (HTLV)

Requested for surveillance

no

Notice required

no

Routine turnaround time

5 working days

Sample requirements

Serum or plasma minimum 500 µL

Pre-transport requirements

5 ± 3°C for less than 24 hours

Transport requirements

Ambient temperature, via overnight courier to arrive within 24 hours.

 

Do not dispatch samples on Friday, Saturday or the day before a public holiday.

Unacceptable sample types

Insufficient sample ≤ 500 µL, haemolysed or lipaemic sample

How results reported

HTLV-1 and HTLV-2 antibodies detected or not detected

Test form number

PHFS6047

Referral link

Download form